<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-25 23-39-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 4/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 2.8 kHz -49 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 28 kHz 5460 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
0,9 dBr 2,18 dBr 3,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 23:39, 25.04.2024
RT
"AFFAIRES SENSIBLES - FRANCE INTER 1ERE RADIO DE FRANCE "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F209, F222, F202, F206
FM Scope Station: 100.20 MHz, signal: 4/5 (36 dBuV) Max at: 28 kHz MIN: 20 kHz % above 75 kHz: 0,0000 Acquired: 2024/04/25 23:38:48 Total samples: 5460 Equivalent time: 0:04:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 3,4 dBr MIN: 0,9 dBr AVE: 2,18 dBr % above 10,2 dBr: 0,0 Last value: 2,4 dBr (2024/04/25 23:38:47) Station: 100.20 MHz, signal: 4/5 (36 dBuV) 23:26 23:28 23:30 23:32 23:34 23:36 23:38 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality